{"title":"Hire - Rent Loggers","description":"\u003cp\u003eHire an Electrocorder logger when you need recorded electrical evidence for a short investigation, load survey, energy audit or voltage complaint without purchasing the equipment outright.\u003c\/p\u003e\n\u003cp\u003eLogger hire is useful for temporary site studies, fault finding, one-off surveys and proof-of-performance checks. Choose the hire product that matches the measurement you need: voltage, current, power, energy or full three-phase power-factor analysis.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/products-by-use\"\u003eChoose the right logger by application\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"rental-electrocorder-ct-3a-rs-three-phase-current-logger-for-industry-and-light-commercial","title":"Hire Electrocorder CT-3A-RS Three Phase Current Logger (60A\/200A or 60A\/400A)","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder CT-3A-RS by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder CT-3A-RS for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need to record three-phase current over time on circuits where clamp-on current transformers are practical. The CT-3A-RS records current data using three CT sensors that fit around conductors up to approximately 30 mm diameter, with model-dependent high ranges of 200 A or 400 A.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase load surveys on smaller conductors.\u003c\/li\u003e\n\u003cli\u003eFeeder loading checks and current-consumption investigations.\u003c\/li\u003e\n\u003cli\u003eEnergy audits where current trends help identify usage patterns.\u003c\/li\u003e\n\u003cli\u003eSites where clamp-on current transformers are convenient and sufficient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eYou need larger current range or flexible sensors for large conductors, where the EC-3A-RS may be a better fit.\u003c\/li\u003e\n\u003cli\u003eYou need voltage, current, power, energy and power factor together, where the EC-7VAR-RS is more appropriate.\u003c\/li\u003e\n\u003cli\u003eYou need voltage-only monitoring, where an EC-3V or SL-3V voltage recorder may be simpler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eCT-3A-RS logger in the smaller 190 x 120 x 60 mm enclosure.\u003c\/li\u003e\n\u003cli\u003eThree clamp-on current transformers for conductors up to approximately 30 mm diameter.\u003c\/li\u003e\n\u003cli\u003eUSB download lead, carry case, 12 Vdc power supply, batteries, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"90%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/OKLn4RLdGi0?controls=0\u0026amp;modestbranding=1\" height=\"272\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The CT-3A-RS is intended for current-only studies where the circuit can be monitored with clamp-on current transformers. It is a practical choice for routine load checks and smaller three-phase current surveys.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the CT-3A-RS records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase current using clamp-on current transformers.\u003c\/li\u003e\n\u003cli\u003eLow range 0.5 A to 60 A.\u003c\/li\u003e\n\u003cli\u003eHigh range 4 A to 200 A or 4 A to 400 A, depending on model.\u003c\/li\u003e\n\u003cli\u003eTRMS average, minimum and maximum values across the selected averaging period.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eThe logger is built into a rugged 190 x 120 x 60 mm enclosure and supplied with clamp-on current transformers, USB lead, carry case and external 12 Vdc power supply. External power is recommended when available to preserve the internal batteries.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the CT-3A-RS datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable class=\"cke_show_border\" height=\"46\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Three Phase Current Logger Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?19\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?19\" alt=\"Three Phase Current Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-DS-En.pdf\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-DS-En.pdf?23\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Three Phase Current Logger User Instructions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?19\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?19\" alt=\"Three Phase Current Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-UI-En.pdf\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-UI-En.pdf?23\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Three Phase Current Logger Datasheet (Spanish)\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?19\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?19\" alt=\"Three Phase Current Logger Datasheet (Spanish)\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-DS-Es.pdf\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-DS-Es.pdf?23\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet (Español)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the CT-3A-RS\u003c\/strong\u003e\u003cbr\u003eChoose this model when you need a current-only three-phase logger for smaller conductors and routine load surveys.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf you need larger conductor access or higher current ranges, consider the EC-3A-RS with flexible Rogowski coils. If you need voltage, current, power and power factor together, consider the EC-7VAR-RS.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree clamp-on current transformers for practical current-only installation.\u003c\/li\u003e\n\u003cli\u003eDual ranges for low-current and higher-current monitoring.\u003c\/li\u003e\n\u003cli\u003eNo voltage connection required for logging.\u003c\/li\u003e\n\u003cli\u003eConfigurable averaging period for short investigations or longer-term monitoring.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration or changing load events.\u003c\/li\u003e\n\u003cli\u003eTamper-resistant setup after configuration in Electrosoft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eThe CT-3A-RS records current only. It is useful for current trend analysis and load surveys, but it does not calculate kW, kVA, kVAR or power factor by itself.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: CT-3A-RS-5H-IP43-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-3A-RS-Order-Code.jpg?20\" alt=\"CT-3A-RS product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I choose the CT-3A-RS?\u003c\/strong\u003e\u003cbr\u003eChoose it for current-only three-phase monitoring on conductors where clamp-on CTs are practical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between CT-3A-RS and EC-3A-RS?\u003c\/strong\u003e\u003cbr\u003eThe CT-3A-RS uses clamp-on current transformers for smaller conductors. The EC-3A-RS uses flexible Rogowski coils and suits larger conductors or higher current ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it need a voltage connection?\u003c\/strong\u003e\u003cbr\u003eNo. It is a current logger, so it does not need an AC voltage connection for logging.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz \/ 400A","offer_id":40292916854870,"sku":"RENTAL-CT-3A-RS-5H-4-IP65","price":115.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 200A","offer_id":30279861469270,"sku":"RENTAL-CT-3A-RS-5H-2-IP65","price":115.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 400A","offer_id":40292916887638,"sku":"RENTAL-CT-3A-RS-6Z-4-IP65","price":115.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 200A","offer_id":30279861502038,"sku":"RENTAL-CT-3A-RS-6Z-2-IP65","price":115.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/rental-electrocorder-ct-3a-rs-three-phase-current-logger-for-industry-and-light-commercial-648922.png?v=1570696279"},{"product_id":"rental-electrocorder-ec-3a-rs-current-logger-for-industrial-and-commercial-appliances","title":"Hire Electrocorder EC-3A-RS Three Phase Current Recorder (400A\/3kA)","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-3A-RS by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-3A-RS for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need to record three-phase current over time, especially on larger industrial or commercial loads where a conventional clamp logger may not have enough current range. The EC-3A-RS uses three flexible Rogowski coils that fit around conductors up to 140 mm diameter and records TRMS average, minimum and maximum current values throughout the selected averaging period.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase load surveys on high-current circuits.\u003c\/li\u003e\n\u003cli\u003eFeeder loading checks and current-consumption investigations.\u003c\/li\u003e\n\u003cli\u003eEnergy audits where current trends are enough to identify major load patterns.\u003c\/li\u003e\n\u003cli\u003eSites where flexible Rogowski coils are easier to fit than clamp current transformers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eYou need voltage, current, power, energy and power factor together, where the EC-7VAR-RS is a better fit.\u003c\/li\u003e\n\u003cli\u003eYou only need lower current ranges on smaller conductors, where the CT-3A-RS may be simpler.\u003c\/li\u003e\n\u003cli\u003eYou need voltage-only monitoring, where an EC-3V or SL-3V voltage recorder may be more appropriate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eEC-3A-RS logger in the smaller 190 x 120 x 60 mm enclosure.\u003c\/li\u003e\n\u003cli\u003eThree flexible Rogowski current sensors for conductors up to 140 mm diameter.\u003c\/li\u003e\n\u003cli\u003eUSB download lead, carry case, 12 Vdc power supply, batteries, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe height=\"272\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/pQerfV5fhaQ?controls=0\u0026amp;modestbranding=1\" width=\"90%\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The EC-3A-RS is intended for current-only studies where larger current ranges or flexible sensors are needed. Because it does not require a voltage connection, it is often quicker to install than a full power logger.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the EC-3A-RS records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase current using flexible Rogowski coils.\u003c\/li\u003e\n\u003cli\u003eDual current ranges: 4 A to 400 A and 30 A to 3 kA.\u003c\/li\u003e\n\u003cli\u003eTRMS average, minimum and maximum values across the selected averaging period.\u003c\/li\u003e\n\u003cli\u003eLong-term trend data for load surveys, energy audits and fault investigations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eThe logger is built into a rugged 190 x 120 x 60 mm enclosure and is supplied with a protective carry case, flexible Rogowski coils, USB lead and external 12 Vdc power supply. External power is recommended when available to preserve the internal batteries.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the EC-3A-RS datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable height=\"46\" class=\"cke_show_border\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Three Phase Current Logger Datasheet\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" title=\"Three Phase Current Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-DS-En.pdf?52\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-DS-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Three Phase Current Logger User Instructions\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" title=\"Three Phase Current Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-UI-En.pdf?52\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-UI-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the EC-3A-RS\u003c\/strong\u003e\u003cbr\u003eChoose this model when the main question is how much current a three-phase circuit carries over time, especially where high current range and flexible fitting matter more than voltage or power-factor measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf you need voltage, current, power and power factor together, consider the EC-7VAR-RS. If the conductors are smaller and lower current ranges are enough, consider the CT-3A-RS. If the investigation is about voltage quality or supply variation, consider the EC-3V or SL-3V.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree flexible Rogowski coils for practical fitting around large conductors.\u003c\/li\u003e\n\u003cli\u003eDual current ranges for both moderate and high-current circuits.\u003c\/li\u003e\n\u003cli\u003eCurrent-only installation without a voltage connection.\u003c\/li\u003e\n\u003cli\u003eConfigurable averaging period for short investigations or longer-term monitoring.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration or changing load events.\u003c\/li\u003e\n\u003cli\u003eTamper-resistant setup: once configured on a PC, site personnel cannot alter logging parameters from the logger.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eBecause the EC-3A-RS is a current-only logger, it is useful for load surveys and current trend analysis, but it does not calculate kW, kVA, kVAR or power factor by itself. Use a power logger such as the EC-7VAR-RS when those values are needed.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-3A-RS-5H-IP65-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-Order-Code.png?52\" alt=\"EC-3A-RS product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I choose the EC-3A-RS?\u003c\/strong\u003e\u003cbr\u003eChoose it for three-phase current-only monitoring where larger current ranges or flexible Rogowski coils are needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it measure voltage or power factor?\u003c\/strong\u003e\u003cbr\u003eNo. The EC-3A-RS is a current logger. For voltage, current, power, energy and power factor together, consider the EC-7VAR-RS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy use Rogowski coils?\u003c\/strong\u003e\u003cbr\u003eRogowski coils are flexible and can be easier to fit around large conductors or awkward busbar\/cable arrangements than rigid clamp sensors.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz","offer_id":30279878312022,"sku":"RENTAL-EC-3A-RS-5H-IP65","price":115.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz","offer_id":30279878344790,"sku":"RENTAL-EC-3A-RS-6Z-IP65","price":115.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/rental-electrocorder-ec-3a-rs-current-logger-for-industrial-and-commercial-appliances-389961.png?v=1570696279"},{"product_id":"rental-electrocorder-ec-3v-three-phase-voltage-logger-for-commercial-and-industrial-applications","title":"Hire Electrocorder EC-3V, 3 Phase Voltage Logger","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-3V by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-3V for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need to understand how a single-phase or three-phase voltage supply behaves over time. The EC-3V can record one, two or three phases using four voltage leads for L1, L2, L3 and neutral, helping identify voltage variation, high or low voltage events, and supply trends.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase voltage monitoring and supply-voltage investigations.\u003c\/li\u003e\n\u003cli\u003eVoltage optimisation checks before and after changes.\u003c\/li\u003e\n\u003cli\u003eInvestigating machines tripping, resetting or behaving unpredictably.\u003c\/li\u003e\n\u003cli\u003eLong-term monitoring where voltage variation needs evidence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eYou need voltage and current together, where the EC-7VAR-RS may be a better fit.\u003c\/li\u003e\n\u003cli\u003eYou need a smaller compact three-phase voltage recorder, where the SL-3V may be sufficient.\u003c\/li\u003e\n\u003cli\u003eYou only need single-phase plug-in voltage monitoring, where an EC-1V or EC-2V may be simpler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eEC-3V logger in the smaller 190 x 120 x 60 mm enclosure.\u003c\/li\u003e\n\u003cli\u003eFour voltage leads for L1, L2, L3 and neutral.\u003c\/li\u003e\n\u003cli\u003eUSB download lead, carry case, batteries, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe height=\"272\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/pQerfV5fhaQ?controls=0\u0026amp;modestbranding=1\" width=\"90%\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The EC-3V is intended for voltage-only investigations where the question is whether the supply voltage is too high, too low, unstable, unbalanced or changing over time.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the EC-3V records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eOne, two or three phase voltages.\u003c\/li\u003e\n\u003cli\u003eTRMS average, minimum and maximum values across the selected averaging period.\u003c\/li\u003e\n\u003cli\u003eVoltage trends, dips, rises and supply variation over time.\u003c\/li\u003e\n\u003cli\u003eDate and time information for recorded voltage events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eThe EC-3V is built into a rugged 190 x 120 x 60 mm enclosure and supplied with fused voltage leads, USB lead, carry case and batteries. It should be installed by a competent person, generally an electrician or engineer.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the EC-3V datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable height=\"46\" class=\"cke_show_border\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Three Phase Current Logger Datasheet\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" title=\"Three Phase Current Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-DS-En.pdf?52\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-DS-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Three Phase Current Logger User Instructions\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" title=\"Three Phase Current Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-UI-En.pdf?52\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3V-UI-EVA77-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the EC-3V\u003c\/strong\u003e\u003cbr\u003eChoose this model when you need a dedicated three-phase voltage recorder and do not need current, power or power-factor data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf you need a smaller three-phase voltage recorder, consider the SL-3V. If you need voltage, current, power and power factor together, consider the EC-7VAR-RS. For simple single-phase plug-in monitoring, consider the EC-1V or EC-2V.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eRecords one, two or three phases using four voltage leads.\u003c\/li\u003e\n\u003cli\u003eDesigned for voltage quality, supply variation and voltage optimisation studies.\u003c\/li\u003e\n\u003cli\u003eConfigurable averaging period for short investigations or longer-term monitoring.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration voltage events.\u003c\/li\u003e\n\u003cli\u003eTamper-resistant setup after configuration in Electrosoft.\u003c\/li\u003e\n\u003cli\u003eSuitable for supply-voltage checks, high\/low voltage investigations and machine reset\/tripping enquiries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eThe EC-3V is a voltage recorder. It does not measure current, power or power factor. Use a power logger such as the EC-7VAR-RS when those relationships matter.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-3V-5H-IEC-IP43-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-Order-Code.png?52\" alt=\"EC-3V product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I choose the EC-3V?\u003c\/strong\u003e\u003cbr\u003eChoose it when you need to record one, two or three phase voltages over time and do not need current or power-factor data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it record a single phase?\u003c\/strong\u003e\u003cbr\u003eYes. The EC-3V can record one, two or three phases depending on how it is connected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between EC-3V and SL-3V?\u003c\/strong\u003e\u003cbr\u003eBoth are three-phase voltage recorders. The SL-3V is a smaller compact model, while the EC-3V is the larger standard model.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz \/ IEC - Bn\/Bk\/Gy\/Be","offer_id":30279894532182,"sku":"RENTAL-EC-3V-5H-IEC","price":100.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ ANZ - Rd\/We\/Be\/Bk","offer_id":30279894499414,"sku":"RENTAL-EC-3V-5H-ANZ","price":100.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ NOR - Bk\/We\/Bn\/Be","offer_id":30279894564950,"sku":"RENTAL-EC-3V-5H-NOR","price":100.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ IEC - Bn\/Bk\/Gy\/Be","offer_id":30279894630486,"sku":"RENTAL-EC-3V-6Z-IEC","price":100.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ CAN - Rd\/Bk\/Be\/We","offer_id":30279894597718,"sku":"RENTAL-EC-3V-6Z-CAN","price":100.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ USA - Bk\/Rd\/Be\/We","offer_id":30279894663254,"sku":"RENTAL-EC-3V-6Z-USA","price":100.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/rental-electrocorder-ec-3v-three-phase-voltage-logger-for-commercial-and-industrial-applications-305140.jpg?v=1570696277"},{"product_id":"rental-electrocorder-ec-7var-rs-three-phase-voltage-current-power-factor-data-logger","title":"Hire Electrocorder EC-7VAR-RS, 3 Phase Voltage, Current \u0026 Power Factor Data Logger","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-7VAR-RS by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-7VAR-RS for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need to understand how a three-phase electrical system behaves over time. The EC-7VAR-RS records phase voltages and phase currents using three flexible Rogowski coils and four voltage leads for L1, L2, L3 and neutral, then provides the data needed to analyse kW, kVAR, kVA, peak demand, power factor and highest and lowest voltage and current values with dates and times.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase load surveys, feeder loading checks and energy audits.\u003c\/li\u003e\n\u003cli\u003eInvestigating voltage, current and power factor behaviour on industrial or commercial sites.\u003c\/li\u003e\n\u003cli\u003eChecking whether low voltage is related to high current demand on site.\u003c\/li\u003e\n\u003cli\u003eUPS sizing, standby generator sizing and temporary power studies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSimple single-phase appliance monitoring, where the AL-2VA or EC-2VA may be a better fit.\u003c\/li\u003e\n\u003cli\u003eVoltage-only investigations, where a three-phase voltage recorder such as the EC-3V may be sufficient.\u003c\/li\u003e\n\u003cli\u003eCurrent-only studies, where a CT-3A-RS or EC-3A-RS current logger may be simpler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eEC-7VAR-RS logger in the smaller 190 x 120 x 60 mm enclosure.\u003c\/li\u003e\n\u003cli\u003eThree flexible Rogowski current sensors suitable for fitting around conductors up to 140 mm diameter.\u003c\/li\u003e\n\u003cli\u003eFour fused voltage leads for L1, L2, L3 and neutral.\u003c\/li\u003e\n\u003cli\u003eUSB download lead, carry case, batteries, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"90%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/pQerfV5fhaQ?controls=0\u0026amp;modestbranding=1\" height=\"272\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The EC-7VAR-RS is intended for three-phase investigations where voltage, current, power and power factor need to be understood together.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the EC-7VAR-RS records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eThree-phase voltages and phase currents.\u003c\/li\u003e\n\u003cli\u003ekW, kVAR, kVA, peak demand and power factor.\u003c\/li\u003e\n\u003cli\u003eHighest and lowest voltage and current values with dates and times.\u003c\/li\u003e\n\u003cli\u003eLong-term trend data for load surveys, energy audits and fault investigations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eThe logger is designed to be installed by a competent person, generally an electrician or engineer. If suitable isolated test points are available, it can often be fitted without interrupting the supply.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the EC-7VAR-RS datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable class=\"cke_show_border\" height=\"46\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Three Phase Current Logger Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" alt=\"Three Phase Current Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-7VAR-RS-DS-En.pdf?v=1731589856\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-DS-En.pdf?52\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Three Phase Current Logger User Instructions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?49\" alt=\"Three Phase Current Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-7VAR-RS-UI-En-EVA77.pdf?v=1731589856\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-UI-En.pdf?52\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the EC-7VAR-RS\u003c\/strong\u003e\u003cbr\u003eChoose this model when the investigation needs a full three-phase picture rather than voltage-only or current-only data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf only current is needed, consider CT-3A-RS or EC-3A-RS. If only voltage is needed, consider EC-3V. If the job is single-phase, consider EC-2VA, CT-2VA or AL-2VA depending on the installation.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eRecords voltage, current, power, energy and power factor together.\u003c\/li\u003e\n\u003cli\u003eThree flexible Rogowski coils for practical fitting around larger conductors.\u003c\/li\u003e\n\u003cli\u003eFour fused voltage leads for L1, L2, L3 and neutral.\u003c\/li\u003e\n\u003cli\u003eUseful for energy audits, load surveys, fault finding and temporary power studies.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration or changing load events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eThe EC-7VAR-RS is a three-phase power logger. It should be installed by a competent person where voltage leads and current sensors are being connected.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-7VAR-RS-5H-IEC-IP43-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-3A-RS-Order-Code.png?52\" alt=\"EC-7VAR-RS product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I hire the EC-7VAR-RS?\u003c\/strong\u003e\u003cbr\u003eHire it when you need a temporary three-phase logger for voltage, current, power, energy and power factor analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for energy audits?\u003c\/strong\u003e\u003cbr\u003eYes. It is one of the best rental choices for three-phase energy audits and load surveys.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it measure all three phase voltages and currents?\u003c\/strong\u003e\u003cbr\u003eYes. It uses three flexible current sensors and four voltage leads for L1, L2, L3 and neutral.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz \/ IEC - Bn\/Bk\/Gy\/Be \/ IP43","offer_id":30279913766998,"sku":"RENTAL-EC-7VAR-RS-5H-IEC-IP43","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ IEC - Bn\/Bk\/Gy\/Be \/ IP65","offer_id":30279913832534,"sku":"RENTAL-EC-7VAR-RS-5H-IEC-IP65","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ ANZ - Rd\/We\/Be\/Bk \/ IP43","offer_id":30279913701462,"sku":"RENTAL-EC-7VAR-RS-5H-ANZ-IP43","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ ANZ - Rd\/We\/Be\/Bk \/ IP65","offer_id":30279913734230,"sku":"RENTAL-EC-7VAR-RS-5H-ANZ-IP65","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ NOR - Bk\/We\/Bn\/Be \/ IP43","offer_id":30279913865302,"sku":"RENTAL-EC-7VAR-RS-5H-NOR-IP43","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ NOR - Bk\/We\/Bn\/Be \/ IP65","offer_id":30279913898070,"sku":"RENTAL-EC-7VAR-RS-5H-NOR-IP65","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ IEC - Bn\/Bk\/Gy\/Be \/ IP43","offer_id":30279913996374,"sku":"RENTAL-EC-7VAR-RS-6Z-IEC-IP43","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ IEC - Bn\/Bk\/Gy\/Be \/ IP65","offer_id":30279914029142,"sku":"RENTAL-EC-7VAR-RS-6Z-IEC-IP65","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ CAN - Rd\/Bk\/Be\/We \/ IP43","offer_id":30279913930838,"sku":"RENTAL-EC-7VAR-RS-6Z-CAN-IP43","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ CAN - Rd\/Bk\/Be\/We \/ IP65","offer_id":30279913963606,"sku":"RENTAL-EC-7VAR-RS-6Z-CAN-IP65","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ USA - Bk\/Rd\/Be\/We \/ IP43","offer_id":30279914061910,"sku":"RENTAL-EC-7VAR-RS-6Z-USA-IP43","price":135.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ USA - Bk\/Rd\/Be\/We \/ IP65","offer_id":30279914127446,"sku":"RENTAL-EC-7VAR-RS-6Z-USA-IP65","price":135.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/rental-electrocorder-ec-7var-rs-three-phase-voltage-current-power-factor-data-logger-372241.png?v=1570696280"},{"product_id":"hire-electrocorder-ct-2va-power-and-energy-recorder","title":"Hire Electrocorder CT-2VA Power and Energy Recorder","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder CT-2VA by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder CT-2VA for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need to record voltage and current together on a single-phase circuit, then review power and energy behaviour over time. The CT-2VA is suited to distribution boards, meter boards and circuits where a clamp-on current transformer can be fitted around the conductor.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSingle-phase power and energy monitoring on accessible circuits.\u003c\/li\u003e\n\u003cli\u003eChecking whether low voltage is related to high current demand.\u003c\/li\u003e\n\u003cli\u003eEnergy audits and load surveys on smaller single-phase circuits.\u003c\/li\u003e\n\u003cli\u003eFacilities and maintenance investigations where voltage and current need to be compared.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eYou need a flexible current sensor for larger conductors, where the EC-2VA may be a better fit.\u003c\/li\u003e\n\u003cli\u003eYou need plug-in appliance monitoring, where the AL-2VA may be easier to use.\u003c\/li\u003e\n\u003cli\u003eYou need three-phase power and power factor, where the EC-7VAR-RS is more appropriate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eCT-2VA logger.\u003c\/li\u003e\n\u003cli\u003eClamp-on current transformer, voltage lead with plug, USB lead, carry case, battery, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003cli\u003eA single-phase power and energy logger for circuits where a CT can be clipped around the conductor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The CT-2VA is intended for single-phase power and energy studies where a clamp-on CT is practical.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the CT-2VA records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSingle-phase voltage and current.\u003c\/li\u003e\n\u003cli\u003ePower and energy values derived from the voltage and current measurements.\u003c\/li\u003e\n\u003cli\u003eMinimum, maximum and average values over the selected averaging period.\u003c\/li\u003e\n\u003cli\u003eData for comparing voltage behaviour with current demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eThe logger is typically installed by a competent person at a distribution board, meter board or suitable circuit. If isolated test points or a mains socket are available, it can often be fitted without interrupting the supply.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the CT-2VA datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable height=\"46\" class=\"cke_show_border\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Single Phase Power Logger Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" alt=\"Single Phase Power Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-2VA-DS-UK-En.pdf\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-DS-UK-En.pdf?49\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg title=\"Single Phase Energy Logger User Instructions\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" alt=\"Single Phase Energy Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-2VA-UI-En.pdf\" data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-UI-En.pdf?49\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the CT-2VA\u003c\/strong\u003e\u003cbr\u003eChoose this model when you need single-phase voltage, current, power and energy data and a clamp-on CT is physically suitable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf a flexible coil is easier to fit, consider the EC-2VA. If the load plugs into a standard socket, consider the AL-2VA. For three-phase systems, consider the EC-7VAR-RS.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eRecords single-phase voltage and current together.\u003c\/li\u003e\n\u003cli\u003eClamp-on CT current sensing.\u003c\/li\u003e\n\u003cli\u003eUseful for energy monitoring, voltage\/current correlation and load studies.\u003c\/li\u003e\n\u003cli\u003eConfigurable averaging period for short or longer-term monitoring.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration or changing load events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eBecause the CT-2VA measures voltage and current together, it can support power and energy analysis. It should be installed by a competent person where access to conductors or distribution equipment is required.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: CT-2VA-5H-UK-IP65-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/CT-2VA-Order-Codes_480x480.jpg?v=1682519484\" alt=\"CT-2VA product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the CT-2VA used for?\u003c\/strong\u003e\u003cbr\u003eIt is used for single-phase voltage, current, power and energy monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it different from EC-2VA?\u003c\/strong\u003e\u003cbr\u003eThe CT-2VA uses a clamp-on current transformer. The EC-2VA uses a flexible Rogowski coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it help explain low-voltage problems?\u003c\/strong\u003e\u003cbr\u003eYes. Because it records voltage and current together, it can help show whether low voltage coincides with high current demand.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz \/ 1A to 200A \/ UK - BS1363\/IS401","offer_id":40246254403670,"sku":"RENTAL-CT-2VA-5H-UK-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 4A to 400A \/ UK - BS1363\/IS401","offer_id":40246254436438,"sku":"RENTAL-CT-2VA-5H-UK-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 1A to 200A \/ AZ - AS3112","offer_id":40246254469206,"sku":"RENTAL-CT-2VA-5H-AZ-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 4A to 400A \/ AZ - AS3112","offer_id":40246254501974,"sku":"RENTAL-CT-2VA-5H-AZ-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 1A to 200A \/ EU - CEE 7\/16","offer_id":40246254534742,"sku":"RENTAL-CT-2VA-5H-EU-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 4A to 400A \/ EU - CEE 7\/16","offer_id":40246254567510,"sku":"RENTAL-CT-2VA-5H-EU-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 1A to 200A \/ SA - SABS1661","offer_id":40246254600278,"sku":"RENTAL-CT-2VA-5H-SA-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 4A to 400A \/ SA - SABS1661","offer_id":40246254633046,"sku":"RENTAL-CT-2VA-5H-SA-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 1A to 200A \/ C14 - IEC C14","offer_id":40246254665814,"sku":"RENTAL-CT-2VA-5H-C14-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 4A to 400A \/ C14 - IEC C14","offer_id":40246254698582,"sku":"RENTAL-CT-2VA-5H-C14-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 1A to 200A \/ C14 - IEC C14","offer_id":40246254731350,"sku":"RENTAL-CT-2VA-6Z-C14-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 4A to 400A \/ C14 - IEC C14","offer_id":40246254764118,"sku":"RENTAL-CT-2VA-6Z-C14-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 1A to 200A \/ NA - NEMA 5\/15","offer_id":40246254796886,"sku":"RENTAL-CT-2VA-6Z-NA-200-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 4A to 400A \/ NA - NEMA 5\/15","offer_id":40246254829654,"sku":"RENTAL-CT-2VA-6Z-NA-400-IP65","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/hire-electrocorder-ct-2va-power-and-energy-recorder-719515.jpg?v=1686366793"},{"product_id":"hire-electrocorder-ec-1v-voltage-recorder","title":"Hire Electrocorder EC-1V Voltage Recorder","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-1V by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-1V for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need a simple way to record true RMS voltage, minimum voltage and maximum voltage from a standard socket. The EC-1V is especially useful when a logger needs to be sent to a customer or remote site so voltage evidence can be collected without arranging an engineer visit.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSingle-phase voltage complaints and supply-voltage investigations.\u003c\/li\u003e\n\u003cli\u003eMailing or couriering a recorder to a customer with a reported voltage problem.\u003c\/li\u003e\n\u003cli\u003eBefore-and-after checks for voltage optimisation work.\u003c\/li\u003e\n\u003cli\u003eFacilities, maintenance and utility support teams that need simple plug-in voltage evidence.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eYou need live-to-neutral and earth-to-neutral voltage channels, where the EC-2V may be a better fit.\u003c\/li\u003e\n\u003cli\u003eYou need voltage and current together, where an EC-2VA, CT-2VA or EC-7VAR-RS may be more appropriate.\u003c\/li\u003e\n\u003cli\u003eYou need three-phase voltage monitoring, where the EC-3V or SL-3V may be a better choice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eEC-1V logger.\u003c\/li\u003e\n\u003cli\u003eVoltage lead, USB lead, hard carry case, battery, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003cli\u003eA small, portable voltage recorder that can be posted to customers or used on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The EC-1V is intended for practical voltage-only investigations where the main question is whether the local voltage is too high, too low, unstable or changing over time.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the EC-1V records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSingle-phase true RMS voltage.\u003c\/li\u003e\n\u003cli\u003eMinimum, maximum and true average voltage values over the selected averaging period.\u003c\/li\u003e\n\u003cli\u003eVoltage dips, swells and long-term supply-voltage trends.\u003c\/li\u003e\n\u003cli\u003eDate and time information for reviewing voltage behaviour.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eWhen fitted with a suitable plug or voltage lead, the EC-1V can be used by non-specialist site staff following instructions. It is commonly mailed to customers with reported voltage issues, then returned for data download and analysis.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the EC-1V datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable height=\"46\" class=\"cke_show_border\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Single Phase Voltage Logger Datasheet\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" title=\"Single Phase Voltage Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-DS-UK-En.pdf?41\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-DS-UK-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Single Phase Voltage Logger User Instructions\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" title=\"Single Phase Voltage Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-2V-UI-En.pdf?41\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-2V-UI-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Single Phase Voltage Logger User Instructions (French)\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" title=\"Single Phase Voltage Logger User Instructions (French)\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"\/Portals\/0\/product-datasheets\/EC-1V\/User Instructions (Français).pdf\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-UI-Fr.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (Français)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Single Phase Voltage Logger User Instructions (Portuguese)\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?41\" title=\"Single Phase Voltage Logger User Instructions (Portuguese)\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-UI-Pt.pdf?41\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-UI-Pt.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eUser Instructions (Português)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the EC-1V\u003c\/strong\u003e\u003cbr\u003eChoose this model when the priority is simple single-phase voltage evidence, especially where the logger may need to be posted or used by someone without access to a distribution board.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf earth-to-neutral voltage is important, consider the EC-2V. If current, power or energy are also needed, consider the EC-2VA, CT-2VA or AL-2VA depending on the installation. For three-phase voltage, consider the EC-3V or SL-3V.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSmall single-phase voltage recorder for socket-level monitoring.\u003c\/li\u003e\n\u003cli\u003eRecords true RMS voltage, minimum voltage and maximum voltage.\u003c\/li\u003e\n\u003cli\u003eSuitable for voltage complaints, optimisation checks and long-term supply monitoring.\u003c\/li\u003e\n\u003cli\u003eSimple field use when supplied with the correct plug or lead arrangement.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration voltage events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eThe EC-1V is a voltage recorder. It does not measure current, power or power factor.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-1V-5H-AZ-IP65-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-1V-Order-Code.png?41\" alt=\"EC-1V product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the EC-1V described as mailable?\u003c\/strong\u003e\u003cbr\u003eIt is small enough to send to customers or remote sites so voltage data can be collected without a site visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the EC-1V measure?\u003c\/strong\u003e\u003cbr\u003eIt records single-phase true RMS voltage, including minimum, maximum and true average values.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it help with voltage optimisation checks?\u003c\/strong\u003e\u003cbr\u003eYes. It can record voltage before and after optimisation so the change can be reviewed with evidence.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz \/ UK - BS1363\/IS401","offer_id":40246254862422,"sku":"RENTAL-EC-1V-5H-UK-IP65","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ AZ - AS3112","offer_id":40246254895190,"sku":"RENTAL-EC-1V-5H-AZ-IP65","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ EU - CEE 7\/16","offer_id":40246254927958,"sku":"RENTAL-EC-1V-5H-EU-IP65","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ SA - SABS1661","offer_id":40246254960726,"sku":"RENTAL-EC-1V-5H-SA-IP65","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ IEC – IEC6H","offer_id":40246254993494,"sku":"RENTAL-EC-1V-5H-IEC-IP65","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ IEC – IEC6H","offer_id":40246255026262,"sku":"RENTAL-EC-1V-6Z-IEC-IP65","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ NA - NEMA 5\/15","offer_id":40246255059030,"sku":"RENTAL-EC-1V-6Z-NA-IP65","price":85.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/hire-electrocorder-ec-1v-voltage-recorder-331319.jpg?v=1686366796"},{"product_id":"hire-electrocorder-ec-2va-power-logger-and-energy-recorder","title":"Hire Electrocorder EC-2VA Power Logger and Energy Recorder","description":"\u003ch5\u003eHire\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-2VA by the week.\u003c\/strong\u003e\u003cbr\u003eFor one week hire, enter quantity \u003cstrong\u003e1\u003c\/strong\u003e. For two weeks, enter quantity \u003cstrong\u003e2\u003c\/strong\u003e. For three weeks, enter quantity \u003cstrong\u003e3\u003c\/strong\u003e, and so on.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHow hire periods are counted:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003e1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003e3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.\u003c\/li\u003e\n\u003cli\u003ePart weeks are rounded up to the next whole week.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou are responsible for returning the logger to us after the hire period has finished, using your own courier.\u003c\/p\u003e\n\n\u003ch5\u003eOverview\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHire the Electrocorder EC-2VA for temporary logging work.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse it when you need to understand how a single-phase circuit or item of equipment behaves over time, including whether low voltage is linked to high current demand. The EC-2VA combines a voltage connection with a flexible Rogowski current sensor, making it useful where conductors are larger or where a split flexible coil is easier to fit.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eGood hire choice for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSingle-phase power and energy monitoring.\u003c\/li\u003e\n\u003cli\u003eInvestigating whether voltage problems are related to current demand.\u003c\/li\u003e\n\u003cli\u003eLoad surveys on circuits where a flexible Rogowski coil is easier to fit.\u003c\/li\u003e\n\u003cli\u003eEnergy audits and consumption checks on single-phase loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eConsider another hire model if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eYou need a clamp-on CT rather than a flexible coil, where the CT-2VA may be simpler.\u003c\/li\u003e\n\u003cli\u003eYou need plug-in appliance monitoring, where the AL-2VA may be easier to use.\u003c\/li\u003e\n\u003cli\u003eYou need three-phase power and power factor, where the EC-7VAR-RS is more appropriate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eHire kit includes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eEC-2VA logger.\u003c\/li\u003e\n\u003cli\u003eFlexible Rogowski current sensor, voltage input lead, USB lead, carry case, batteries, user instructions and free Electrosoft analysis software.\u003c\/li\u003e\n\u003cli\u003eA detachable-coil system that can support different physical coil sizes where required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch5\u003eApplications\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eTypical hire applications:\u003c\/strong\u003e The EC-2VA is intended for single-phase power and energy investigations where voltage and current need to be understood together.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eWhat the EC-2VA records:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eSingle-phase voltage and current.\u003c\/li\u003e\n\u003cli\u003ePower and energy values derived from the voltage and current measurements.\u003c\/li\u003e\n\u003cli\u003eMinimum, maximum and true average values over the selected averaging period.\u003c\/li\u003e\n\u003cli\u003eData for checking whether voltage changes are related to current demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy constant sampling matters:\u003c\/strong\u003e the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.\u003c\/p\u003e\n\u003cp\u003eThe logger is typically fitted by a competent person at a distribution board, meter board or suitable test point. The Rogowski coil opens at the joint so it can be placed around a conductor without breaking the main circuit.\u003c\/p\u003e\n\u003cp\u003eAfter logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.\u003c\/p\u003e\n\n\u003ch5\u003eResources\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e\u003cbr\u003eDownload the EC-2VA datasheet and user instructions for detailed technical information, installation guidance and operating instructions.\u003c\/p\u003e\n\u003ctable height=\"46\" class=\"cke_show_border\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Single Phase Power Logger Datasheet\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" title=\"Single Phase Power Logger Datasheet\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-DS-UK-En.pdf?49\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-DS-UK-En.pdf\" target=\"_blank\"\u003e\u003cstrong\u003eDatasheet\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg alt=\"Single Phase Energy Logger User Instructions\" data-cke-saved-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/PDF_Icon_baff24dc-e625-4c76-ad42-bfe6a8a17d93.png?46\" title=\"Single Phase Energy Logger User Instructions\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca data-cke-saved-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-UI-En.pdf?49\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-DP-UI-En.pdf?v=1770198769\" target=\"_blank\" title=\"EC-2VA User Instructions\" rel=\"noopener\"\u003e\u003cstrong\u003eUser Instructions (English)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eFree Electrosoft PC software\u003c\/strong\u003e\u003cbr\u003eElectrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.\u003c\/p\u003e\n\u003cp\u003eElectrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 1em; margin-bottom: 1.5em;\" border=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width: 90px; padding: 10px 14px; border: 1px solid #e2e2e2; vertical-align: middle; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/Electrosoft_Icon_d3991672-01de-431e-8f5d-b336bbdcc959.png?101\" alt=\"Electrosoft software icon\" style=\"max-width: 48px; height: auto;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 18px; border: 1px solid #e2e2e2; vertical-align: middle;\"\u003e\u003ca href=\"https:\/\/electrocorder.com\/pages\/downloads\"\u003e\u003cstrong\u003eDownload Electrosoft PC software\u003c\/strong\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eWhen to hire the EC-2VA\u003c\/strong\u003e\u003cbr\u003eChoose this model when the investigation needs single-phase voltage, current, power and energy data and a flexible current sensor is useful.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompare with related hire models\u003c\/strong\u003e\u003cbr\u003eIf a clamp-on CT is a better physical fit, consider the CT-2VA. If the load plugs into a standard socket, consider the AL-2VA. For three-phase systems, consider the EC-7VAR-RS.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 0;\"\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0; margin-bottom: 1.25em; padding-left: 1.25em; list-style: disc;\"\u003e\n\u003cli\u003eRecords single-phase voltage and current together.\u003c\/li\u003e\n\u003cli\u003eFlexible Rogowski coil can fit around larger conductors.\u003c\/li\u003e\n\u003cli\u003eUseful for energy monitoring, voltage\/current correlation and load studies.\u003c\/li\u003e\n\u003cli\u003eDetachable coil arrangement allows coil changes where supported.\u003c\/li\u003e\n\u003cli\u003eConstant sampling to reduce the risk of missing short-duration or changing load events.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement note\u003c\/strong\u003e\u003cbr\u003eBecause the EC-2VA measures voltage and current together, it can support power and energy analysis. It should be installed by a competent person where access to conductors or distribution equipment is required.\u003c\/p\u003e\n\u003cp style=\"margin-top: 1.5em; margin-bottom: 0;\"\u003e\u003cstrong\u003eDetermining product order codes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-2VA-5H-UK-IP65-SET.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/files\/EC-2VA-Order-Codes_480x480.jpg?v=1682519380\" alt=\"EC-2VA product order code diagram\" style=\"max-width: 100%; height: auto;\"\u003e\u003c\/p\u003e\n\n\u003ch5\u003eFAQ\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose the hire length?\u003c\/strong\u003e\u003cbr\u003eUse the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen does the hire clock start?\u003c\/strong\u003e\u003cbr\u003eThe hire clock starts the day after delivery and includes one extra day after the logging period for return.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWho returns the logger?\u003c\/strong\u003e\u003cbr\u003eYou are responsible for returning the logger to us after the hire period using your own courier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the EC-2VA used for?\u003c\/strong\u003e\u003cbr\u003eIt is used for single-phase voltage, current, power and energy monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose a Rogowski coil?\u003c\/strong\u003e\u003cbr\u003eA Rogowski coil is flexible and can be easier to fit around larger conductors or awkward cable arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it different from CT-2VA?\u003c\/strong\u003e\u003cbr\u003eThe EC-2VA uses a flexible Rogowski coil. The CT-2VA uses a clamp-on current transformer.\u003c\/p\u003e","brand":"Electrocorder","offers":[{"title":"5H - 50Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ UK - BS1363\/IS401","offer_id":40246255091798,"sku":"RENTAL-EC-2VA-5H-UK-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ AZ - AS3112","offer_id":40246255124566,"sku":"RENTAL-EC-2VA-5H-AZ-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ EU - CEE 7\/16","offer_id":40246255157334,"sku":"RENTAL-EC-2VA-5H-EU-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ SA - SABS1661","offer_id":40246255190102,"sku":"RENTAL-EC-2VA-5H-SA-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ IEC – IEC6H","offer_id":40246255222870,"sku":"RENTAL-EC-2VA-5H-IEC-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ UK - BS1363\/IS401","offer_id":40246255255638,"sku":"RENTAL-EC-2VA-5H-UK-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ AZ - AS3112","offer_id":40246255288406,"sku":"RENTAL-EC-2VA-5H-AZ-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ EU - CEE 7\/16","offer_id":40246255321174,"sku":"RENTAL-EC-2VA-5H-EU-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ SA - SABS1661","offer_id":40246255353942,"sku":"RENTAL-EC-2VA-5H-SA-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"5H - 50Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ IEC – IEC6H","offer_id":40246255386710,"sku":"RENTAL-EC-2VA-5H-IEC-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ IEC – IEC6H","offer_id":40246255419478,"sku":"RENTAL-EC-2VA-6Z-IEC-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 300A - 140mm\/5\" Coil (Orange) \/ NA - NEMA 5\/15","offer_id":40246255452246,"sku":"RENTAL-EC-2VA-6Z-NA-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ IEC – IEC6H","offer_id":40246255485014,"sku":"RENTAL-EC-2VA-6Z-IEC-IP65","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"6Z - 60Hz \/ 300A - Both 50mm\/2” \u0026 140mm\/5\" Coil \/ NA - NEMA 5\/15","offer_id":40246255517782,"sku":"RENTAL-EC-2VA-6Z-NA-IP65","price":95.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0261\/9503\/4198\/products\/hire-electrocorder-ec-2va-power-logger-and-energy-recorder-100697.png?v=1686366794"}],"url":"https:\/\/electrocorder.com\/collections\/rental-loggers\/power.oembed","provider":"Electrocorder","version":"1.0","type":"link"}