Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder
  • Load image into Gallery viewer, Hire Electrocorder EC-1V Voltage Recorder

Hire Electrocorder EC-1V Voltage Recorder

Regular price
£85.00 GBP
Sale price
£85.00 GBP
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.

Hire

Hire the Electrocorder EC-1V by the week.
For one week hire, enter quantity 1. For two weeks, enter quantity 2. For three weeks, enter quantity 3, and so on.

How hire periods are counted:

  • 1 week hire gives 9 days in total: the hire clock starts the day after delivery, allows 7 days of logging, and includes one extra day to return the logger.
  • 2 week hire gives 16 days in total: the hire clock starts the day after delivery, allows 14 days of logging, and includes one extra day to return the logger.
  • 3 week hire gives 23 days in total: the hire clock starts the day after delivery, allows 21 days of logging, and includes one extra day to return the logger.
  • Part weeks are rounded up to the next whole week.

You are responsible for returning the logger to us after the hire period has finished, using your own courier.

Overview

Hire the Electrocorder EC-1V for temporary logging work.

Use it when you need a simple way to record true RMS voltage, minimum voltage and maximum voltage from a standard socket. The EC-1V is especially useful when a logger needs to be sent to a customer or remote site so voltage evidence can be collected without arranging an engineer visit.

Good hire choice for:

  • Single-phase voltage complaints and supply-voltage investigations.
  • Mailing or couriering a recorder to a customer with a reported voltage problem.
  • Before-and-after checks for voltage optimisation work.
  • Facilities, maintenance and utility support teams that need simple plug-in voltage evidence.

Consider another hire model if:

  • You need live-to-neutral and earth-to-neutral voltage channels, where the EC-2V may be a better fit.
  • You need voltage and current together, where an EC-2VA, CT-2VA or EC-7VAR-RS may be more appropriate.
  • You need three-phase voltage monitoring, where the EC-3V or SL-3V may be a better choice.

Hire kit includes:

  • EC-1V logger.
  • Voltage lead, USB lead, hard carry case, battery, user instructions and free Electrosoft analysis software.
  • A small, portable voltage recorder that can be posted to customers or used on site.
Applications

Typical hire applications: The EC-1V is intended for practical voltage-only investigations where the main question is whether the local voltage is too high, too low, unstable or changing over time.

What the EC-1V records:

  • Single-phase true RMS voltage.
  • Minimum, maximum and true average voltage values over the selected averaging period.
  • Voltage dips, swells and long-term supply-voltage trends.
  • Date and time information for reviewing voltage behaviour.

Why constant sampling matters: the Electrocorder samples throughout the averaging period, helping capture short events, changing loads and trend data that can be missed by periodic snapshots.

When fitted with a suitable plug or voltage lead, the EC-1V can be used by non-specialist site staff following instructions. It is commonly mailed to customers with reported voltage issues, then returned for data download and analysis.

After logging, connect the logger to a PC by USB and use Electrosoft to view, save, export and report on the results.

Resources

Documentation:
Download the EC-1V datasheet and user instructions for detailed technical information, installation guidance and operating instructions.

Single Phase Voltage Logger Datasheet Datasheet
Single Phase Voltage Logger User Instructions User Instructions (English)
Single Phase Voltage Logger User Instructions (French) User Instructions (Français)
Single Phase Voltage Logger User Instructions (Portuguese) User Instructions (Português)

Free Electrosoft PC software
Electrosoft is compatible with Windows 11 down to Windows 7. It lets you view and zoom current, power and energy graphs, export data to Microsoft Excel, email results to colleagues, and print or save reports as PDF files with your company logo.

Electrosoft includes statistics, load balancing, tariff and costing analysis, annual CO2 and energy usage projections, logger management and calibration management tools. Sample files are included so you can try the software without having a logger connected.

Electrosoft software icon Download Electrosoft PC software
Features

When to hire the EC-1V
Choose this model when the priority is simple single-phase voltage evidence, especially where the logger may need to be posted or used by someone without access to a distribution board.

Compare with related hire models
If earth-to-neutral voltage is important, consider the EC-2V. If current, power or energy are also needed, consider the EC-2VA, CT-2VA or AL-2VA depending on the installation. For three-phase voltage, consider the EC-3V or SL-3V.

Key features:

  • Small single-phase voltage recorder for socket-level monitoring.
  • Records true RMS voltage, minimum voltage and maximum voltage.
  • Suitable for voltage complaints, optimisation checks and long-term supply monitoring.
  • Simple field use when supplied with the correct plug or lead arrangement.
  • Constant sampling to reduce the risk of missing short-duration voltage events.

Measurement note
The EC-1V is a voltage recorder. It does not measure current, power or power factor.

Determining product order codes:

To specify your Electrocorder select various codes and enter into the boxes in order to create an accurate product code. For example: EC-1V-5H-AZ-IP65-SET.

EC-1V product order code diagram

FAQ

How do I choose the hire length?
Use the product quantity as the number of whole weeks required. Part weeks are rounded up to the next whole week.

When does the hire clock start?
The hire clock starts the day after delivery and includes one extra day after the logging period for return.

Who returns the logger?
You are responsible for returning the logger to us after the hire period using your own courier.

Why is the EC-1V described as mailable?
It is small enough to send to customers or remote sites so voltage data can be collected without a site visit.

What does the EC-1V measure?
It records single-phase true RMS voltage, including minimum, maximum and true average values.

Can it help with voltage optimisation checks?
Yes. It can record voltage before and after optimisation so the change can be reviewed with evidence.