How to use
The CT-3A-RS is a three-phase dual range, 0.5A to 60A, 4A to 200A or 400A (model dependent), current data logger that just needs its clamp-on current transformers connected to your incoming supply. Setup the Logger using the Electrosoft software, then fit it to the distribution board or other point that you're going to measure. CT’s fit around 30mm diameter cables.
What you get:-
Logger
Current Sensors (CT’s fit around 30mm diameter cables.)
USB Lead
Carry Case
Batteries
Software
12Vdc Power Supply
User Instructions
As no voltage input is required, you can fit easily as a competent person without necessarily requiring an electrician or engineer, and may not require any power interruption at all. Once you're set up, just press the Start button to start logging! The onboard indicator will flash Green when logging.
When the logger's finished recording (or you've captured enough data!) just disconnect from supply, hook it up to your PC and download the information. Electrosoft will let you view the data immediately on-screen and save or export for later analysis.
For a demonstration of how to use the logger, please watch our video below.
Description
Ideal analysis logger for Energy Audits
The affordable Electrocorder is the best value solution for carrying out site audits, with great analysis and reporting tools in our free software. Our focus on providing an easy to deploy energy analyzer with built-in equipment management tools helps to make logging as effective as possible. Tamper-proof setup means that installers or other personnel can't casually change or view logging parameters and invalidate data.
Designed for extended Volt-free Logging
Operates on replaceable batteries for up to 3 months of volt-free logging when needed, with optional external power input for extended life. Rugged and reliable, with IP65 environmental sealing as standard!
Never miss data with Constant Sampling
Constant Sampling ensures that you never miss any data, with minimum and maximum values displayed across the averaging period. Records for up to 50 days to EN50160 standard. Averaging period can be set from 1 second to 60 minutes (301 days). Many other loggers will only take data snapshots, meaning that you miss crucial trend data.
Industry Standard
Electrocorder is the market leader in energy and power analysis and fault diagnosis, used to troubleshoot and resolve customer complaints by electricity network suppliers throughout Europe such as Dalkia, SSE, Electricity North West, ESB Networks and NIE Networks. Supplied Worldwide to utilities, industry and electrical contractors. Acksen has been designing and manufacturing Power Quality Loggers since 1994, using our expertise to provide highly robust and reliable equipment - so much that we're prepared to offer a free lifetime warranty on all our Loggers (conditions apply).
Perfect for Load Surveys/Feeder Loading Analysis
The CT-3A-RS is used by facilities management, contractors, electrical/site services and maintenance engineers to monitor loading variations on site helping them to diagnose any load related issues. Also used for UPS sizing and monitoring and standby generator sizing and monitoring. Perfect for gathering data to make a case for splitting-up the loading or increasing feeder or transformer capacity. Designed to be accurate at current levels from 0.5A to 200A/400A (model dependent), to allow monitoring of light commercial, small industrial, farms and domestic/residential loads. The CTs fit around cables of diameter 30mm (1.2") or less.
Included with your Energy Data Logger Kit
Everything you need to operate is included - no hidden extras required!
Electrocorder CT-3A-RS with 3x clamp-on current transformers (CTs) (CT’s fit around 30mm diameter cables.)
USB Download Cable.
Carrying Case.
12Vdc PSU.User Instructions.
Free analysis software download.Free Electrosoft PC Software
Free Electrosoft software (compatible with Windows 11 down to Vista) allows you to view and zoom on Current, Power and Energy graphs. Data can be exported to Microsoft Excel in one click or emailed to colleagues. A wide range of analysis reports can be printed or saved as PDF files with your company logo!
Electrosoft includes many more industry-leading features such as Statistics and Load Balancing, Tariff & Costing Analysis with Annual CO2 and Energy usage projections, Logger Management Database and Calibration Management tools.
Electrosoft also includes sample files so you can download and try it out now without needing a logger!
Harmonised Code: 9030.3901.00 (electronic datalogger)
Origin: Northern Ireland, United Kingdom.
Packaged dimensions: 2.5kg, 30x26x17cm.
Datasheet | |
User Instructions (English) | |
Datasheet (Español) |
Determining product order codes: |